01
It blocks risky work until approval is clear.
Hot work, electrical isolation, confined space entry, working at height, excavation, and other risk types can require a signed permit before the job proceeds.
Governance · Safety authorization
When a job involves hot work, electrical isolation, confined space entry, working at height, excavation, or another non-routine risk, Infodeck attaches a permit workflow to the work. A named applicant requests approval. A facility owner or safety approver signs off before the crew proceeds.
Named applicant. Named approver. Pre-work checks and close-out evidence on one record.
London HQ · Level 4 Plant Room
Assignee
Marcus K.
In-house team
Scheduled
26 Apr 2026
22:00 to 02:00 local
Site
London HQ
Level 4 Plant Room
Trade
Electrical
Planned isolation
Work start request
Every permit carries a named applicant, approver, work window, location, and work type before high-risk work is allowed to begin.
The facility owner or safety approver can require serial sign-off, independent approval, and pre-work evidence before the job moves forward.
The crew completes pre-work checks, post-work close-out, and delegated sign-off on the same operating record.
Plain answers
Permit to work software controls high-risk facility work before it starts, names the applicant and approver, records safety checks, and keeps close-out evidence on the work record.
01
Hot work, electrical isolation, confined space entry, working at height, excavation, and other risk types can require a signed permit before the job proceeds.
02
Each permit records who requested the work, who approved it, where it applies, when it is valid, what hazards were declared, and which controls were required.
03
Pre-work checks, delegated checklist responses, post-work checks, signatures, timestamps, and field changes remain on the same record for later review.
01 · Applicant and approver
A work order says what needs doing. A permit to work says who is asking to perform a risky activity, where it will happen, when it is valid, what hazards are declared, and who is responsible for allowing it on the facility.
Infodeck keeps that separation explicit. The applicant can be an in-house supervisor or a contractor crew lead. The approver can be the facility owner, compliance lead, or safety officer. Each signature records the person, role, time, and decision.
SafetyCulture gives you checklists. Facilio gives you safety forms. Infodeck ties the permit to the operating record, so high-risk work waits until authorization is signed.
Linked to WR-2026-1855 · Roof membrane repair · Block A roof deck
Step 1 · Submit permit request
SubmittedLiam O. · In-house supervisor
23 Apr 2026 · 14:22
Step 2 · Compliance review
ApprovedFatima H. · Compliance officer
23 Apr 2026 · 16:05 · note "crew credentials checked"
Step 3 · Safety officer issue
In progressSara T. · Safety officer
Due 24 Apr 2026 · 12:00
Step 4 · Pre-work check
QueuedCrew lead · delegated to Priya S.
Unlocks after step 3 issues the permit
02 · Template library
Every permit snapshots the rule it was issued under.
Hot work is not the same as excavation. Electrical isolation is not the same as working at height. Compliance defines a template for each permit type: required approvers, validity window, pre-work checklist, post-work checklist, hazards, PPE, and who can apply.
Welding · cutting · grinding
Pre · Post · 8h validity
Tanks · vessels · ducts
Pre · Post · 12h validity
Used on WR-2026-1901 tonight
Pre · Post · 6h validity
Above 2m · roof work
Pre · Post · 10h validity
Trenching · ground breaking
Pre · Post · 24h validity
Your own work type
Every permit issued from the template carries a snapshot of those rules at the moment it was created. If compliance tightens the template next quarter, permits already in flight keep the standard they started under. No retroactive rule change.
03 · Pre-work checks
The site still has to be made safe.
Once the permit is approved, the crew still has to prove the work area is ready. The template names the pre-work checklist: hazards reviewed, PPE verified, site conditions photographed, isolations confirmed, and any work-type controls completed. Each response stamps onto the permit record, named to the person who signed. If the work order requires that permit, Infodeck will not let active work proceed until the authorization and required checks are present.
Sparks, adjacent combustibles, confined airflow. Named, not implied.
FR coveralls, arc-rated gloves, harness, fire watch. Each item ticked by hand.
Photos on the checklist, stamped to the person who signed.
04 · Delegated checklist
No account required.
When the permit allows delegation, the supervisor generates a secure link for a named email. The link lands in the recipient's inbox with a 48-hour expiry. They open it on whatever device they have, complete the checklist, and submit. No login, no account, no new software for the crew.
The delegate cannot be the person who issued the delegation. Self-approval is refused by the engine. Whoever signs the check is not the same person who asked them to sign.
Supervisor view
Hot work · Sunrise Facilities
Send pre-work check to
delegate@example.com
Block A roof deck
Hazards declared
Live voltage · Arc flash
PPE required
FR coveralls · Arc-rated gloves · Harness · Fire watch
Signing as
Priya S. · Crew lead · Sunrise Facilities
Secure link. No account needed. Expires 24 Apr 2026 · 18:22.
05 · Close-out
When the work is done, someone attaches the post-work checklist response. The permit moves to post-work pending. A closing sign-off step, usually compliance or the facility owner, confirms the site is safe to hand back. The permit lands at closed. Expired permits terminate without a sign-off. Cancelled permits close with a reason on the record.
Close-out is not a phone call or a chat message. The closed record carries the applicant, approver, crew, hazards declared, PPE verified, every approval signature, every checklist response, and the timestamps for each.
Linked to WR-2026-1901 · Feeder panel L4-E2 · Level 4 Plant Room
Pre-work response
Marcus K. · 26 Apr 2026 · 22:08
AttachedPost-work response
Marcus K. · 27 Apr 2026 · 01:52
AttachedApprovals ledger
Audit timeline
Submitted
Liam O. · 25 Apr 14:22
Approved by compliance
Fatima H. · 25 Apr 18:05
Issued by safety officer
Sara T. · 26 Apr 12:45
Started
Marcus K. · 26 Apr 22:08
Post-work submitted
Marcus K. · 27 Apr 01:52
Pending closing sign-off
Assigned to Fatima H.
Expired permits terminate without sign-off. Cancelled permits close with a reason on the record.
06 · Audit trail
Every state change on a permit writes an audit row. Permit created, permit approved, permit started, post-work submitted, permit closed, permit cancelled. Each row carries the actor, the timestamp, the field changes, and the permit id. The crew members are named. The hazards declared are on the record. The PPE required is on the record. The contractor company and the contact are on the record.
When the auditor asks which permit covered the electrical isolation on Block A on the night of 2026-04-17, the answer is on the record. Reconstruct the day from the permit. No spreadsheet cross-reference.
Contractor licensing, renewal cases, and compliance scorecard live on contractor-governance. This page does not repeat that scope.
07 · Same inbox
Pre-work and post-work sign-offs appear on the same approvals inbox that carries quotation, visitor, and work-order decisions, so the safety lane is one tab for your approvers, not a separate app.
See the platform
30-minute demo. Bring your real permit types, approval rules, and close-out requirements. We will walk through the request, approval, pre-work check, and final record.
Related paths